INSPECTION



Check the following points; replace the part if a problem is found.

INLET MANIFOLD CHECK


1.Check for damage or cracking of any part.
2.Clogging of the negative pressure (vacuum) outlet port.
3.Using a straight edge and feeler gauge, check for distortion of the cylinder head installation surface <4G6, 6B3>.
<4G6, 6B3>
    Standard value: 0.15 mm or less
    Limit: 0.20 mm