HIGH/LOW DETECTION SWITCH CONTINUITY CHECK <V5MB1>



Check the continuity between terminals of the white connector and earth indicated in the illustration.
Transfer lever position
Specified condition
While switching between 4HLc and 4LLc
Open circuit
2H, 4H, 4HLc and 4LLc
Continuity (Less than 2 Ω)