TRANSFER INSPECTION



TRANSFER ACTUATOR CONTINUITY CHECK



TRANSFER LIMIT SWITCH CHECK



Check for the continuity between the connector terminals.
Transfer limit switch number
Switch condition
Terminal number
Normal condition
Transfer limit switch 1
ON
1, 9 - 4
Continuity (Less than 2Ω)
OFF
1, 9 - 4
No continuity
Transfer limit switch 2
ON
1, 9 - 3
Continuity (Less than 2Ω)
OFF
1, 9 - 3
No continuity
Transfer limit switch 3
ON
1, 9 - 2
Continuity (Less than 2Ω)
OFF
1, 9 - 2
No continuity

HIGH-LOW LIMIT SWITCH CHECK



Check for the continuity between the connector terminals.
High-Low limit switch number
Switch condition
Terminal number
Normal condition
High-Low limit switch 1
ON
1, 9 - 7
Continuity (Less than 2Ω)
OFF
1, 9 - 7
No continuity
High-Low limit switch 2
ON
1, 9 - 8
Continuity (Less than 2Ω)
OFF
1, 9 - 8
No continuity

TRANSFER MOTOR CHECK



Check for the resistance between the connector terminals.
Terminal number
Normal condition
5 - 6
Less than 100Ω

HIGH-LOW MOTOR CHECK



Check for the resistance between the connector terminals.
Terminal number
Normal condition
11 - 12
Less than 100Ω