DOOR LATCH ASSEMBLY INSPECTION



Check the door lock actuator operation in the following procedures:
1.Open a door that is supposed to be checked.
2.Remove a door trim assembly (Refer to GROUP 52A - Door Trim ).
3.Use a screwdriver or the like to slide the door latch claw from unlatch to full-latch position (Set the door latch from door-open to door-closed condition).

DOOR LOCK ACTUATOR





ACTUATOR OPERATION CHECK <RH>
Claw position
Door inside handle lock knob position
Battery connection
Door inside handle lock knob operation
Full-latch
Lock

  • Connect terminal 4 to negative battery terminal.
  • Connect terminal 3 to positive battery terminal.

Knob moves from "Lock" to "Unlock" position.
Full-latch
Unlock

  • Connect terminal 4 to positive battery terminal.
  • Connect terminal 3 to negative battery terminal.

Knob moves from "Unlock" to "Lock" position.

ACTUATOR OPERATION CHECK <LH>
Claw position
Door inside handle lock knob position
Battery connection
Door inside handle lock knob operation
Full-latch
Lock

  • Connect terminal 1 to negative battery terminal.
  • Connect terminal 2 to positive battery terminal.

Knob moves from "Lock" to "Unlock" position.
Full-latch
Unlock

  • Connect terminal 1 to positive battery terminal.
  • Connect terminal 2 to negative battery terminal.

Knob moves from "Unlock" to "Lock" position.

ACTUATOR SWITCH CHECK <RH>
Claw position
Door inside handle lock knob position
Tester connection
Specified condition
Full-latch
Lock
7 - 9
No continuity
Full-latch
Unlock
7 - 9
Continuity exists (2 Ω or less)

ACTUATOR SWITCH CHECK <LH>
Claw position
Door inside handle lock knob position
Tester connection
Specified condition
Full-latch
Lock
6 - 8
No continuity
Full-latch
Unlock
6 - 8
Continuity exists (2 Ω or less)