SUNROOF LID GLASS OPERATION CURRENT CHECK




1.Remove the sunroof fuse to check that it is normal, and connect a circuit tester as shown.
2.Turn ON the sunroof switch, then measure the operating current of the intermediary segment except when operation is starting, the sunroof is fully closed, the sunroof is fully opened and the sunroof is tilted fully up.
Standard value: 3 A or less (at 20 °C)
3.Check the following areas if the operating current of the sunroof lid glass is outside the standard value:

  • Improperly installed sunroof assembly, deformation or any foreign substances
  • Improperly fastened drive cable
  • Tilting of sunroof lid glass