INSPECTION



POWER WINDOW MAIN SWITCH CONTINUITY CHECK <Vehicles with (anti-trap) safety system)>





<FRONT PASSENGER’S SWITCH (LHD)>
Switch position
Tester connection
Specified condition
UP
7* - 14, 15 - 16
Continuity exists (2 Ω or less)
OFF
7* - 14, 7 *- 15
DOWN
14 - 16, 7* - 15
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S LEFT SWITCH (LHD)>
Switch position
Tester connection
Specified condition
UP
1 -7*, 2 - 16
Continuity exists (2 Ω or less)
OFF
1 -7*, 2 -7*
DOWN
2 -7*, 1 - 16
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S RIGHT SWITCH (LHD)>
Switch position
Tester connection
Specified condition
UP
7* - 8, 9 - 16
Continuity exists (2 Ω or less)
OFF
7* - 8, 7* - 9
DOWN
7* - 9, 8 - 16
note *: Set the window lock switch to UNLOCK position.

POWER WINDOW MAIN SWITCH CONTINUITY CHECK <Vehicles without (anti-trap) safety system (Vehicles with driver’s side auto down mechanism)>





<FRONT PASSENGER’S SWITCH (LHD)>
Switch position
Tester connection
Specified condition
UP
10* - 11, 7 - 12
Continuity exists (2 Ω or less)
OFF
10* - 11, 10 *- 12
DOWN
7 - 11, 10* - 12
note *: Set the window lock switch to UNLOCK position.

<FRONT PASSENGER’S SWITCH (RHD)>
Switch position
Tester connection
Specified condition
UP
10* - 8, 7 - 9
Continuity exists (2 Ω or less)
OFF
10* - 8, 10* - 9
DOWN
10* - 9, 7- 8
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S LEFT SWITCH (LHD)>
Switch position
Tester connection
Specified condition
UP
1 -10*, 2 - 7
Continuity exists (2 Ω or less)
OFF
1 -10*, 2 -10*
DOWN
2 -10*, 1 - 7
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S LEFT SWITCH (RHD)>
Switch position
Tester connection
Specified condition
UP
1 -10*, 2 - 7
Continuity exists (2 Ω or less)
OFF
1 -10*, 2 -10*
DOWN
1 - 7, 2 -10*
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S RIGHT SWITCH (LHD)>
Switch position
Tester connection
Specified condition
UP
10* - 5, 6 - 7
Continuity exists (2 Ω or less)
OFF
10* - 5, 10* - 6
DOWN
10* - 6, 5 - 7
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S RIGHT SWITCH (RHD)>
Switch position
Tester connection
Specified condition
UP
10* - 5, 6 - 7
Continuity exists (2 Ω or less)
OFF
10* - 5, 10* - 6
DOWN
10* - 6, 5 - 7
note *: Set the window lock switch to UNLOCK position.

POWER WINDOW MOTOR CONTINUITY CHECK





<FRONT DOOR [Vehicles without (anti-trap) safety system]>
Battery connection
Slider position

  • Connect terminal No. 1 to the negative battery terminal.
  • Connect terminal No. 2 to the positive battery terminal.

UP

  • Connect terminal No. 2 to the negative battery terminal.
  • Connect terminal No. 1 to the positive battery terminal.

DOWN