Inspection Procedure 1: Power of the multivision display does not turn ON when the ignition switch is in the "ACC" position or "ON" position.



caution Before replacing the multivision display, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.

OPERATION


When the ignition switch is in the ON or ACC position, the multivision display power can be turned ON. With the multivision display power ON, when the ignition switch is turned to the OFF position, the power for multivision display is also turned OFF.

COMMENTS ON TROUBLE SYMPTOM


Provided that the audio diagnosis code is not set, if the power for multivision display cannot be turned ON, the multivision display, or power supply circuit for multivision display may have a problem.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Voltage measurement at smartphone link display audio connector.


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Ignition switch: "ACC" position
(3)Check the voltage between the smartphone link display audio connector (ACC terminal) and body earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 3.
Go to Step 2.

STEP 2. Check of short to power supply, short to earth and open circuit in ACC line between smartphone link display audio connector and ignition switch (ACC)


Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction).
Repair the connector(s) or wiring harness.

STEP 3. Voltage measurement at smartphone link display audio connector (+B terminal).


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Check the voltage between the smartphone link display audio connector (+B terminal) and body earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 5.
Go to Step 4.

STEP 4. Check of short to power supply, short to earth, and open circuit +B line between fusible link and smartphone link display audio connector.


Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction).
Repair the wiring harness.

STEP 5. Check of short to open circuit in GND line between smartphone link display audio connector and body earth


Q. Is the check result normal?

Go to Step 6.
Repair the wiring harness.

STEP 6. Retest the system


Check if the multivision display power is turned ON.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction).
Replace the multivision display (Refer to ).