Code No. P0513: Immobilizer System <Vehicles with KOS>




FUNCTION



note
  • This code may be displayed due to radio interference if there are multiple registered ignition keys nearby during engine start.
  • This code may be displayed when the transponder ID code is registered.
  • This code is also displayed when the ignition key code is not recognised.
  • When this code is displayed, it is also sent to KOS&OSS-ECU

TROUBLE JUDGEMENT


Check Conditions
Judgement Criterion

FAIL-SAFE AND BACKUP FUNCTION




PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III diagnosis code



  • Reconfirmation whether diagnosis code is set in KOS&OSS-ECU.

Q. Is the diagnosis code set?

Perform the troubleshooting of KOS-system (Refer to GROUP 42B - Troubleshooting - Diagnosis Code Chart ).
Go to Step 2.

STEP 2. M.U.T.-III diagnosis code



  • Reconfirmation of diagnosis code.

Q. Is the diagnosis code set?

Replace the KOS&OSS-ECU. After the replacement, put the each identification code into KOS&OSS-ECU [Refer to GROUP 42B - On-vehicle Service - ID Codes Registration Procedures ]. Then go to Step 3.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).

STEP 3. M.U.T.-III diagnosis code



  • Reconfirmation of diagnosis code.

Q. Is the diagnosis code set?

Replace the engine-ECU.
Check end.