INTAKE AIR TEMPERATURE SENSOR No. 2 CHECK



1.Disconnect the intake air temperature sensor No. 2 connector.
2.Measure resistance between terminals No. 1 and No. 2.
Standard value:
    13 - 18 kΩ (at -20°C)
    5.1 - 6.9 kΩ (at 0°C)
    2.0 - 3.0 kΩ (at 20°C)
    [0.9 - 1.5 kΩ (at 40°C)]
    [0.40 - 0.78 kΩ (at 60°C)]
    0.23 - 0.42 kΩ (at 80°C)
3.Remove the intake air temperature sensor No. 2

4.Measure resistance while heating the sensor using a hair drier.
Normal condition:
Temperature (°C)
Resistance (kΩ)
Higher
Smaller
5.If the value deviates from the standard value or the resistance remains unchanged, replace the intake air temperature sensor No. 2 sensor assembly.
6.Install the air flow sensor and tighten it to the specified torque.
Tightening torque: 14.0 ± 1.0 N·m