REMOVAL AND INSTALLATION


caution
  • When removing or installing the air flow sensor, be careful not to apply impact to the sensor.
  • Do not reuse the air flow sensor that has been dropped.

<4G6>






Removal steps


1.
Air cleaner element

>>B<<
2.
Air flow sensor


3.
O-ring


4.
Air cleaner cover


5.
Air intake hose


·
Breather hose connection (Refer to GROUP 11A - Valve Stem Seal ).


6.
Air intake pipe


7.
Air hose


8.
Air duct


9.
Air cleaner body

<4D5>






Removal steps


1.
Air cleaner element

>>B<<
2.
Air flow sensor <Euro4>


3.
O-ring <Euro4>


4.
Air cleaner cover


·
Breather hose connection (Refer to GROUP 11D - Rocker Cover and Injector ).

>>A<<
5.
Air intake hose


6.
Air duct


7.
Air cleaner body

<4N1>






Removal steps


1.
Air cleaner element

>>B<<
2.
Air flow sensor


3.
O-ring


4.
Air cleaner cover


5.
Air intake hose


6.
Air duct and air cleaner body assembly


7.
Air duct


8.
Air cleaner body

INSTALLATION SERVICE POINTS



>>A<< AIR INTAKE HOSE INSTALLATION



<Vehicles with intercooler (High power engine)>
Clamp vacuum hose with clip of air intake hose beside white marking as shown.

>>B<< AIR FLOW SENSOR INSTALLATION


1.Install the air flow sensor to the air cleaner cover with care not to damage the O-ring.
2.
caution Do not over-tighten. If the mounting screw is over-tightened, the air cleaner cover can be damaged.
Tighten the mounting screws to the specified torque.
Tightening torque:

    <4G6> 1.5 ± 0.3 N·m
    <4D5, 4N1> 0.7 ± 0.1 N·m