REMOVAL AND INSTALLATION <4G6>



caution
  • Do not drop or hit the detonation sensor against other components. Internal damage may result, and the detonation sensor will need to be replaced.
  • When the detonation sensor replacement is performed, use the M.U.T.-III to initialise the learning value (Refer to GROUP 00 - Precautions Before Service, Initialisation Procedure for Learning Value in MPI Engine ).
Pre-removal and Post-installation Operation
  • Inlet Manifold Stay Removal and Installation (Refer to GROUP 15 - Inlet Manifold ).





Removal steps

>>A<<
1.
Detonation sensor

INSTALLATION SERVICE POINT



>>A<< DETONATION SENSOR INSTALLATION



Align the detonation sensor connector to the position shown in the figure, and install it to the cylinder block with the specified torque.
Tightening torque: 20 ± 2 N·m