INSPECTION



INSPECT SOLENOID ASSEMBLY (S2, SR)



INSPECT SOLENOID ASSEMBLY (S1)



1.
caution
  • Do not apply impact to the solenoid assembly.
  • Do not damage the terminals
With a tester, measure the resistance between the solenoid assembly terminal and the solenoid assembly body.
Standard value: 11 - 15Ω (at 20 degrees C)
note If the resistance value is not within the specified, replace the solenoid assembly with a new one.

2.Check that the solenoid assembly operates when connecting the positive battery terminal to the solenoid assembly terminal, and the negative battery terminal to the solenoid assembly body.
note If the solenoid assembly does not operate, replace it with a new one.

3.Check that the valve in the solenoid assembly operates when the solenoid assembly terminal is connected to the positive battery terminal and the solenoid assembly body is connected to the negative battery terminal.
note If the solenoid assembly does not operate, replace it with a new one.
BATTERY POSITIVE VOLTAGE
NORMAL CONDITION
Not applied
Air leaks
Applied
Air maintained

INSPECT SOLENOID ASSEMBLY (S2, SR)



1.
caution
  • Do not apply impact to the solenoid assembly.
  • Do not damage the terminals
With a tester, measure the resistance between the solenoid assembly terminal and the solenoid assembly body.
Standard value: 11 - 15Ω (at 20 degrees C)
note If the resistance value is not within the specified, replace the solenoid assembly with a new one.

2.Check that the solenoid assembly operates when connecting the positive battery terminal to the solenoid assembly terminal, and the negative battery terminal to the solenoid assembly body.
note If the solenoid assembly does not operate, replace it with a new one.

3.Check that the valve in the solenoid assembly operates when the solenoid assembly terminal is connected to the positive battery terminal and the solenoid assembly body is connected to the negative battery terminal.
note If the solenoid assembly does not operate, replace it with a new one.
BATTERY POSITIVE VOLTAGE
NORMAL CONDITION
Not applied
Air maintained
Applied
Air leaks