INSPECTION



REMOTE CONTROLLED MIRROR OPERATION CHECK



Check that the mirror moves as described in the table when each terminal is connected to the battery.
Battery connection
Direction operation

  • Connect terminal 12 to the negative battery terminal.
  • Connect terminal 14 to the positive battery terminal.

Up

  • Connect terminal 12 to the positive battery terminal.
  • Connect terminal 14 to the negative battery terminal.

Down

  • Connect terminal 12 to the negative battery terminal.
  • Connect terminal 13 to the positive battery terminal.

Right

  • Connect terminal 12 to the positive battery terminal.
  • Connect terminal 13 to the negative battery terminal.

Left

  • Connect terminal 10 to the positive battery terminal.
  • Connect terminal 11 to the negative battery terminal.

Return

  • Connect terminal 10 to the negative battery terminal.
  • Connect terminal 11 to the positive battery terminal.

Retract

DOOR MIRROR CONTROL SWITCH CONTINUITY CHECK



Switch position
Tester connection
Specified condition
OFF
9 - 2, 9 - 3, 9 - 6, 9 - 10, 9 - 11, 1 - 2,1 - 3, 1 - 6,
1 -10, 1 - 11
Open circuit
Left side
OFF
9 - 6, 9 - 10, 9 - 11,
1 - 6, 1 - 10, 1 - 11
Open circuit
Up
1 - 6, 9 - 11
Continuity (Less than 2 ohms)
Down
1 - 11, 6 - 9
Right
1 - 6, 9 - 10
Left
1 - 10, 6 - 9
Right side
OFF
9 - 2, 9 - 3, 9 - 6,
1 - 2, 1 - 3, 1 - 6
Open circuit
Up
1 - 6, 3 - 9
Continuity (Less than 2 ohms)
Down
1 - 3, 6 - 9
Right
1 - 6, 2 - 9
Left
1 - 2, 6 - 9
Retract and return
1 - 4
Continuity
(Less than 2 ohms)