CUSTOMISATION FUNCTION


Using the ETACS system of M.U.T.-III, the following functions can be programmed. The programmed information is held even when the battery is disconnected.

<Vehicles for Thailand>
Adjustment item (M.U.T.-III display)
Adjustment item
Adjusting content (M.U.T.-III display)
Adjusting content
Turn power source
Adjustment of turn-signal lamp operation condition
ACC or IG1
Operable with ACC or ON position
IG1
Operable with ON position (Initial condition)
Comfort flasher
With/without comfort flasher function
Disable
No function
Enable
With function (Initial condition)
Comfort flasher switch time
Switch operation time to activate the comfort flasher function
400ms
0.4 second (Initial condition)
800ms
0.8 second
Hazard answer back
Adjustment of the number of keyless hazard warning lamp answer back flashes
Lock:1, Unlock:2
LOCK: Flashes once, UNLOCK: Flashes twice (Initial condition)
Lock:1, Unlock:0
LOCK: Flashes once, UNLOCK: No flash
Lock:0, Unlock:2
LOCK: No flash, UNLOCK: Flash twice
Lock:2, Unlock:1
LOCK: Flash twice, UNLOCK: Flash once
Lock:2, Unlock:0
LOCK: Flash twice, UNLOCK: No flash
Lock:0, Unlock:1
LOCK: No flash, UNLOCK: Flash once
Lock:0, Unlock:0
No function
Vehicle speed-dependent wiper
Disabling or enabling vehicle speed-dependent wiper function
Inhibit
No function
Operation
With function (Initial condition)
Wiper synchronized washer
Disabling or enabling washer-linked wiper function
Inhibit
No function (Only washer operation)
Operation
With function (Initial condition)
Automatic fold door mirror
Electric retractable mirror operation adjustment <Vehicles without keyless entry system>
Not automatic
No synchronised operation
Open vehicle SPD
Vehicle speed-dependent operation (Initial condition)
Open/Close by IG
Ignition switch linked operation
Electric retractable mirror operation adjustment <Vehicles with keyless entry system>
Not automatic
No synchronised operation
Open vehicle SPD
Vehicle speed-dependent operation
Open/Close by IG
Ignition switch linked operation
OPN/CLS Keyless
Keyless entry linked operation (Initial condition)
Headlamp automatic cut customize
Adjustment of headlamp automatic shutdown function
Disable
No function
Enable (B-spec.)
With function (Initial condition)
Room lamp automatic cut timer
Adjustment of interior lamp automatic shutoff function (only room lamp switch is door position)
Disable
No function
About 30min
With function (Initial condition)
Timer lock timer
Timer lock period adjustment
30 sec.
30 seconds (Initial condition)
60 sec.
60 seconds
120 sec.
120 seconds
180 sec.
180 seconds
Multi mode RKE
Multi-mode keyless entry function customisation
Disable
No function
D-spec
Door mirror fold/unfold operation. (Initial condition)
Room lamp delay time:Door Close
Adjustment of interior lamp delay shutdown time
0 sec.
0 second (no delay shutdown time)
7.5 sec.
7.5 seconds
15 sec.
15 seconds (Initial condition)
30 sec.
30 seconds
60 sec.
60 seconds
120 sec.
120 seconds
180 sec.
180 seconds
KOS buzzer answer back
Adjusts the buzzer answer back function.
Not sound buzzer
No function
At KOS
Sounds when KOS is activated. (Initial condition)
At keyless
Sounds when the keyless entry system is activated.
At both
Sounds when the keyless entry system or KOS is activated.
KOS feature
KOS function adjustment
Both enable
All KOS functions are enabled. (Initial condition)
DoorEntry enable
Only door entry function is enabled.
ENG start enable
Only engine starting function is enabled.
Both disable
All KOS functions are disabled.
KOS unlock disable time
Adjusts the door unlock inhibition period after door lock is activated.
0 sec.
0 second
3 sec.
3 seconds (default)
5 sec.
5 seconds
KOS outer buzzer volume
Volume adjustment for the KOS outer buzzer
Volume 1
Quieter than the standard
Volume 2
Standard volume (Initial condition)
Volume 3
Louder than the standard
KOS key detect out from window
With/without KOS key exterior detection function
Disable
No function (Initial condition)
Enable
With function
ACC automatic cut timer (OSS)
Time to ACC power cut-off when the ignition switch is in the ACC position
Disable
No function
30 min
30 minutes (initial condition)
60 min
60 minutes

<Vehicles for Australia and New Zealand>
Adjustment item (M.U.T.-III display)
Adjustment item
Adjusting content (M.U.T.-III display)
Adjusting content
Turn power source
Adjustment of turn-signal lamp operation condition
ACC or IG1
Operable with ACC or ON position
IG1
Operable with ON position (Initial condition)
Comfort flasher
With/without comfort flasher function
Disable
No function
Enable
With function (Initial condition)
Comfort flasher switch time
Switch operation time to activate the comfort flasher function
400ms
0.4 second (Initial condition)
800ms
0.8 second
Hazard answer back
Adjustment of the number of keyless hazard warning lamp answer back flashes
Lock:1, Unlock:2
LOCK: Flashes once, UNLOCK: Flashes twice (Initial condition)
Lock:1, Unlock:0
LOCK: Flashes once, UNLOCK: No flash
Lock:0, Unlock:2
LOCK: No flash, UNLOCK: Flash twice
Lock:2, Unlock:1
LOCK: Flash twice, UNLOCK: Flash once
Lock:2, Unlock:0
LOCK: Flash twice, UNLOCK: No flash
Lock:0, Unlock:1
LOCK: No flash, UNLOCK: Flash once
Lock:0, Unlock:0
No function
Vehicle speed-dependent wiper
Disabling or enabling vehicle speed-dependent wiper function
Inhibit
No function
Operation
With function (Initial condition)
Front wiper operation
Adjustment of the intermittent windshield wiper operation <Vehicles with lighting control sensor (rain sensor)>
Not function
No function
Speed sensitive
Intermittent wiper interval is calculated according to the intermittent wiper volume control and vehicle speed.
Rain sensitive
Intermittent wiper interval is calculated according to the intermittent wiper volume control and lighting control sensor (initial condition).
Wiper synchronized washer
Disabling or enabling washer-linked wiper function
Inhibit
No function (Only washer operation)
Operation
With function (Initial condition)
Automatic fold door mirror
Electric retractable mirror operation adjustment
Not automatic
No synchronised operation
Open vehicle SPD
Vehicle speed-dependent operation
Open/Close by IG
Ignition switch linked operation
OPN/CLS Keyless
Keyless entry linked operation (Initial condition)
Headlamp automatic cut time
Adjustment of headlamp automatic shutdown function
Disable
No function
3min
With function: If the headlamps are turned on with the ignition switch OFF, the system will extinguish all the lamps in three minutes.
1min
With function (Initial condition): If the headlamps are turned on with the ignition switch OFF, the system will extinguish all the lamps in one minute.
Automatic lamp sensitivity (RLS)
Lighting control sensor sensitivity (illumination intensity) <Vehicles with lighting control sensor (rain sensor)>
Level 1 bright
High-high ambient brightness
Level 2 bright
High ambient brightness
Level 3
Standard ambient brightness (initial condition)
Level 4 dark
Low ambient brightness
Level 5 dark
Low-low ambient brightness
Room lamp automatic cut timer
Adjustment of interior lamp automatic shutoff function (only room lamp switch is door position)
Disable
No function
About 30min
With function (Initial condition)
Timer lock timer
Timer lock period adjustment
30 sec.
30 seconds (Initial condition)
60 sec.
60 seconds
120 sec.
120 seconds
180 sec.
180 seconds
Multi mode RKE
Multi-mode keyless entry function customisation
Disable
No function
D-spec
Door mirror fold/unfold operation. (Initial condition)
Room lamp delay time:Door Close
Adjustment of interior lamp delay shutdown time
0 sec.
0 second (no delay shutdown time)
7.5 sec.
7.5 seconds
15 sec.
15 seconds (Initial condition)
30 sec.
30 seconds
60 sec.
60 seconds
120 sec.
120 seconds
180 sec.
180 seconds
KOS buzzer answer back
Adjusts the buzzer answer back function.
Not sound buzzer
No function
At KOS
Sounds when KOS is activated. (Initial condition)
At keyless
Sounds when the keyless entry system is activated.
At both
Sounds when the keyless entry system or KOS is activated.
KOS feature
KOS function adjustment
Both enable
All KOS functions are enabled. (Initial condition)
DoorEntry enable
Only door entry function is enabled.
ENG start enable
Only engine starting function is enabled.
Both disable
All KOS functions are disabled.
KOS unlock disable time
Adjusts the door unlock inhibition period after door lock is activated.
0 sec.
0 second
3 sec.
3 seconds (default)
5 sec.
5 seconds
KOS outer buzzer volume
Volume adjustment for the KOS outer buzzer
Volume 1
Quieter than the standard
Volume 2
Standard volume (Initial condition)
Volume 3
Louder than the standard
KOS key detect out from window
With/without KOS key exterior detection function
Disable
No function (Initial condition)
Enable
With function
ACC automatic cut timer (OSS)
Time to ACC power cut-off when the ignition switch is in the ACC position
Disable
No function
30 min
30 minutes (initial condition)
60 min
60 minutes

<Vehicles for General Export>
Adjustment item (M.U.T.-III display)
Adjustment item
Adjusting content (M.U.T.-III display)
Adjusting content
Turn power source
Adjustment of turn-signal lamp operation condition
ACC or IG1
Operable with ACC or ON position
IG1
Operable with ON position (Initial condition)
Comfort flasher
With/without comfort flasher function
Disable
No function
Enable
With function (Initial condition)
Comfort flasher switch time
Switch operation time to activate the comfort flasher function
400ms
0.4 second (Initial condition)
800ms
0.8 second
Hazard answer back
Adjustment of the number of keyless hazard warning lamp answer back flashes
Lock:1, Unlock:2
LOCK: Flashes once, UNLOCK: Flashes twice (Initial condition)
Lock:1, Unlock:0
LOCK: Flashes once, UNLOCK: No flash
Lock:0, Unlock:2
LOCK: No flash, UNLOCK: Flash twice
Lock:2, Unlock:1
LOCK: Flash twice, UNLOCK: Flash once
Lock:2, Unlock:0
LOCK: Flash twice, UNLOCK: No flash
Lock:0, Unlock:1
LOCK: No flash, UNLOCK: Flash once
Lock:0, Unlock:0
No function
Vehicle speed-dependent wiper
Disabling or enabling vehicle speed-dependent wiper function
Inhibit
No function
Operation
With function (Initial condition)
Front wiper operation
Adjustment of the intermittent windshield wiper operation <Vehicles with lighting control sensor (rain sensor)>
Not function
No function
Speed sensitive
Intermittent wiper interval is calculated according to the intermittent wiper volume control and vehicle speed.
Rain sensitive
Intermittent wiper interval is calculated according to the intermittent wiper volume control and lighting control sensor (initial condition).
Wiper synchronized washer
Disabling or enabling washer-linked wiper function
Inhibit
No function (Only washer operation)
Operation
With function (Initial condition)
Automatic fold door mirror
Electric retractable mirror operation adjustment <Vehicles without keyless entry system>
Not automatic
No synchronised operation
Open vehicle SPD
Vehicle speed-dependent operation (Initial condition)
Open/Close by IG
Ignition switch linked operation
Electric retractable mirror operation adjustment <Vehicles with keyless entry system>
Not automatic
No synchronised operation
Open vehicle SPD
Vehicle speed-dependent operation
Open/Close by IG
Ignition switch linked operation
OPN/CLS Keyless
Keyless entry linked operation (Initial condition)
Headlamp automatic cut customize
Adjustment of headlamp automatic shutdown function
Disable
No function
Enable (B-spec.)
With function (Initial condition)
Door unlock (Shift "P" position)
Adjustment of the selector "P" position-linked door unlocking function <A/T>
Disable
Without function (initial condition)
Enable
With function: Operates when the shift lever or the selector lever is moved to the P position.
Room lamp automatic cut timer
Adjustment of interior lamp automatic shutoff function (only room lamp switch is door position)
Disable
No function
About 30min
With function (Initial condition)
Timer lock timer
Timer lock period adjustment
30 sec.
30 seconds (Initial condition)
60 sec.
60 seconds
120 sec.
120 seconds
180 sec.
180 seconds
Multi mode RKE
Multi-mode keyless entry function customisation
Disable
No function
D-spec
Door mirror fold/unfold operation. (Initial condition)
Room lamp delay time:Door Close
Adjustment of interior lamp delay shutdown time
0 sec.
0 second (no delay shutdown time)
7.5 sec.
7.5 seconds
15 sec.
15 seconds (Initial condition)
30 sec.
30 seconds
60 sec.
60 seconds
120 sec.
120 seconds
180 sec.
180 seconds
KOS buzzer answer back
Adjusts the buzzer answer back function.
Not sound buzzer
No function
At KOS
Sounds when KOS is activated. (Initial condition)
At keyless
Sounds when the keyless entry system is activated.
At both
Sounds when the keyless entry system or KOS is activated.
KOS feature
KOS function adjustment
Both enable
All KOS functions are enabled. (Initial condition)
DoorEntry enable
Only door entry function is enabled.
ENG start enable
Only engine starting function is enabled.
Both disable
All KOS functions are disabled.
KOS unlock disable time
Adjusts the door unlock inhibition period after door lock is activated.
0 sec.
0 second
3 sec.
3 seconds (default)
5 sec.
5 seconds
KOS outer buzzer volume
Volume adjustment for the KOS outer buzzer
Volume 1
Quieter than the standard
Volume 2
Standard volume (Initial condition)
Volume 3
Louder than the standard
KOS key detect out from window
With/without KOS key exterior detection function
Disable
No function (Initial condition)
Enable
With function
ACC automatic cut timer (OSS)
Time to ACC power cut-off when the ignition switch is in the ACC position
Disable
No function
30 min
30 minutes (initial condition)
60 min
60 minutes
Door unlock function by IG lock
Adjustment of the ignition switch "LOCK (OFF)" position-linked door unlocking function
Disable
Without function (initial condition)
Enable
With function: Operates when the ignition switch is moved to the LOCK (OFF) position.