INSPECTION PROCEDURE C-1: Central door locking system does not work.



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.




COMMENT ON TROUBLE SYMPTOM


If the central door locking system does not work at all, the ETACS-ECU may be defective.

POSSIBLE CAUSES



  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


Step 1. Check the central door lock operation with door lock switch


Use the door lock switch to check that the central door locking system works normally.

Q. Is the check result normal?

Go to Step 2 .
Refer to Inspection Procedure C-2 "The central door locking system does not function by using the driver’s door lock switch. ".

Step 2. ECU check by using the SWS monitor


Check that the power supply and earth lines to the ETACS-ECU and the SWS communication lines are normal.

  • Ignition switch: OFF
ECU TO BE CHECKED
  • ETACS ECU
OK: "OK" is displayed on the "ETACS ECU" menu.

Q. Is the check result normal?

Go to Step 3.
Refer to Inspection Procedure A-3 "Communication with the ETACS-ECU is not possible ."

Step 3. Connector check: C-219 ETACS-ECU connector



Q. Is the check result normal?

Go to Step 4.

Repair the defective connector.

Step 4. Check the wiring harness between C-219 ETACS-ECU connector terminal No.2 to fusible link (30).





note Prior to the wiring harness inspection, check intermediate connector C-125 and junction block connector C-204, and repair if necessary.

  • Check the power supply line for open or short circuit.

Q. Is the check result normal?

Go to Step 5.

Repair the wiring harness.

Step 5. Retest the system.


Check that the central door locking system works normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).
Replace the ETACS-ECU.