Code No. B1021,B1022: Air thermo sensor system






COMMENTS ON TROUBLE SYMPTOM


This code is set when the air thermo sensor circuit is open (Code No.B1022) or is short (Code No.B1021).

PROBABLE CAUSES



  • Malfunction of the air thermo sensor
  • Damaged the wiring harness or connectors
  • Malfunction of the automatic air conditioner control panel (A/C-ECU)

DIAGNOSIS PROCEDURE



STEP 1. M.U.T.-III data list


Check that the following service data display contents are normal. (Refer to .)

  • Item 03: Air thermo sensor

Q. Is the check result normal?

Go to Step 5.
Go to Step 2.

STEP 2. Connector check: C-106 A/C-ECU connector and C-05 air thermo sensor connector





Q. Is the check result normal?

Go to Step 3.

Repair the connector.

STEP 3. Check the wiring harness between C-106 A/C-ECU connector (terminals 1 and 19) and C-05 air thermo sensor connector (terminals 2 and 1).






  • Check the sensor signal line and earth line for open or short circuit.

Q. Is the check result normal?

Go to Step 4.

Repair the wiring harness.

STEP 4. Check the air thermo sensor.


Refer to .

Q. Is the check result normal?

Go to Step 5.
Replace the air thermo sensor.

STEP 5. M.U.T.-III diagnosis code


Q. Is the diagnosis code set?

Replace the automatic air conditioner control panel (A/C-ECU).
The trouble can be an intermittent malfunction (Refer to GROUP 00, How to Cope with Intermittent Malfunction ).