INSTALLATION SERVICE POINTS |
>>A<< O-RING / WATER PIPE INSTALLATION |
|
>>B<< WATER PASSAGE GASKET |
Install water passage gasket so
that its side drop comes to the engine inside as shown
in the illustration. |
>>C<< THERMOSTAT INSTALLATION |
Install the thermostat in the
thermostat case with its jiggle valve located at the top
position. |
>>D<< ENGINE COOLANT TEMPERATURE SENSOR INSTALLATION |
When reusing the sensor, apply the
specified sealant to the threads. Specified sealant: 3MTM AAD Part No. 8731 or equivalent |