Inspection Procedure 2: Communication with the ETACS-ECU is not
Possible.
|
caution |
Whenever the ECU is replaced, ensure that the power
supply circuit, the earthing circuit and the communication circuit are
normal.
|
|
|
COMMENTS ON TROUBLE SYMPTOM
|
|
It is suspected that the power supply circuit
to the ETACS-ECU is defective, or the wiring harness between the SWS
monitor and the ETACS-ECU or their connector(s) is damaged. If the battery
power supply circuit to the ECU (terminal No.20 of the ETACS-ECU) is
damaged, also check the power supply circuit from the ignition switch (IG1)
(terminal No.8 of the ETACS-ECU), and repair if necessary. If the earth
circuit to the ECU (terminal No.3 of the ETACS-ECU) is defective, also
check the earth circuit to the sensor (terminal No.56 of the ETACS-ECU),
and repair if necessary.
|
|
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
|
STEP 1. Connector check: D-419 ETACS-ECU connector
|
|
Q.
Is the check result normal?
|
|
Go to Step 2.
|
|
|
|
Repair
the defective connector.
|
|
|
|
STEP 2. Voltage measurement at the D-419 ETACS-ECU
connector.
|
|
(1)Remove the ETACS-ECU, and measure at the junction block
side.
|
|
(2)Voltage between D-419 ETACS-ECU connector terminal No.20
and body earth OK: System voltage
|
|
Q.
Is the check result normal?
|
|
Go to Step 4.
|
|
|
|
Go to Step 3.
|
|
|
|
STEP 3. Check the wiring harness between D-419 ETACS-ECU connector
terminal No.20 and fusible link (1).
|
|
note |
Prior to the wiring harness inspection, check
intermediate connector D-241 and junction block connector D-401, and
repair if necessary.
|
|
|
- Check the power supply line for open circuit.
|
|
Q.
Is the check result normal?
|
|
The
trouble can be an intermittent malfunction (Refer to GROUP 00 - How
to use troubleshooting/Inspection Service Points ).
|
|
|
|
Repair
the wiring harness.
|
|
|
|
STEP 4. Resistance measurement at the D-419 ETACS-ECU
connector.
|
|
(1)Remove the ETACS-ECU, and measure at the junction block
side.
|
|
(2)Resistance between D-419 ETACS-ECU connector terminal No.3
and body earth OK: Continuity exists (2 Ω or
less)
|
|
Q.
Is the check result normal?
|
|
Go to Step 6.
|
|
|
|
Go to Step 5.
|
|
|
|
STEP 5. Check the wiring harness between D-419 ETACS-ECU connector
terminal No.3 to body earth.
|
|
note |
Prior to the wiring harness inspection, check
junction block connector D-405, and repair if necessary.
|
|
|
- Check the earth wires for open circuit.
|
|
Q.
Is the check result normal?
|
|
The
trouble can be an intermittent malfunction (Refer to GROUP 00 - How
to use troubleshooting/Inspection Service Points ).
|
|
|
|
Repair
the wiring harness.
|
|
|
|
STEP 6. Connector check: D-420 ETACS-ECU connector and D-311 column
switch connector
|
|
Q.
Is the check result normal?
|
|
Go to Step 7.
|
|
|
|
Repair
the defective connector.
|
|
|
|
STEP 7. Check the wiring harness from D-420 ETACS-ECU connector
terminal Nos.59 and 68 to D-311 column switch connector terminal Nos.3 and
2.
|
|
- Check the communication lines for open circuit.
|
|
Q.
Is the check result normal?
|
|
Go to Step 8.
|
|
|
|
Repair
the wiring harness.
|
|
|
|
STEP 8. ECU check by using the SWS monitor
|
|
OK: "OK" is displayed on the
"ETACS ECU" menu.
|
|
Q.
Is the check result normal?
|
|
The
trouble can be an intermittent malfunction (Refer to GROUP 00 - How
to use troubleshooting/Inspection Service Points ).
|
|
|
|
Replace the ETACS-ECU.
|
|
|