VARIABLE GEOMETRY CONTROL SOLENOID VALVE CHECK <4D5- High power engine, 4N1>



<4D5- High power engine>



1.Disconnect the vacuum hoses from the variable geometry control solenoid valve.
note When disconnecting the vacuum hose, always make sure that it can be reconnected at its original position.
2.Disconnect the harness connector.

3.Connect a hand vacuum pump to nipple (A) or (B) of the variable geometry control solenoid valve.
4.As described in the chart below, check airtightness by applying a vacuum with voltage applied directly from the battery to the variable geometry control solenoid valve, and without applying voltage.
Battery positive voltage
Nipple (A) condition
Nipple (B) condition
Normal condition
Applied
Connect a hand vacuum pump.
Open
Vacuum leaks
Closed
Vacuum maintained
Not applied
Open
Vacuum maintained
Closed
Connect a hand vacuum pump.
Vacuum leaks

5.Measure the resistance between the terminals of the variable geometry control solenoid valve.
Standard value: 10 - 14 Ω (at 20°C)
6.Replace the solenoid if airtightness or resistance is out of specification.

<4N1>



1.Disconnect the vacuum hoses from the variable geometry control solenoid valve.
note When disconnecting the vacuum hose, always make sure that it can be reconnected at its original position.
2.Disconnect the harness connector.

3.Connect a hand vacuum pump to nipple (A) or (B) of the variable geometry control solenoid valve.
4.As described in the chart below, check airtightness by applying a vacuum with voltage applied directly from the battery to the variable geometry control solenoid valve, and without applying voltage.
Battery positive voltage
Nipple (A) condition
Nipple (B) condition
Normal condition
Applied
Connect a hand vacuum pump.
Open
Vacuum leaks
Closed
Vacuum maintained
Not applied
Open
Vacuum maintained
Closed
Connect a hand vacuum pump.
Vacuum leaks

5.Measure the resistance between the terminals of the variable geometry control solenoid valve.
Standard value: 10 - 14 Ω (at 20°C)
6.Replace the solenoid if airtightness or resistance is out of specification.