VARIABLE GEOMETRY CONTROL SOLENOID VALVE CHECK



1.Disconnect the vacuum hoses from the variable geometry control solenoid valve.
note When disconnecting the vacuum hose, always make sure that it can be reconnected at its original position.
2.Disconnect the harness connector.

3.Measure the resistance between the terminals of the variable geometry control solenoid valve.
Standard value: 10 - 14 Ω (at 20°C)
4.Replace the solenoid if airtightness or resistance is out of specification.