REMOVAL AND INSTALLATION



Pre-removal and Post-installation Operation
  • Removal and Installation of Instrument Lower Panel (Refer to GROUP 52A, Instrument Lower Panel ).
  • Removal and Installation of Glove Box (Refer to GROUP 52A, Glove Box ).
  • Removal and Installation of Instrument centre panel (Refer to GROUP 52A, Instrument Centre Panel ).
  • Removal and Installation of Floor console (Refer to GROUP 52A, Floor Console ).
  • Removal and Installation of Radio and CD player bracket (Refer to GROUP 54A, Radio and CD Player <1DIN TYPE>, <UNIQ TYPE>).





Heater controller assembly removal steps

>>C<<
1.
Outside/Inside air selection damper control cable connection

>>B<<
2.
Air mixing damper control cable connection

>>A<<
3.
Mode selection damper control cable connection


4.
Heater controller assembly

INSTALLATION SERVICE POINTS



>>A<< MODE SELECTION DAMPER CONTROL CABLE CONNECTION




1.Check that the air outlet changeover damper lever is at the FACE position.
2.Set the air outlet changeover knob on the heater control panel to the FACE position.
3.Engage the cable end into the mode link pin of the heater unit assembly.

4.Engage the cable E-ring into the locator of the heater unit assembly to fit the cable into the clip.
5.Operate the air outlet changeover knob to check that it rotates from the FACE to the FOOT, and from the FOOT to the FACE positions smoothly.
6.When the blower unit is running at high speed with the knob set to the FACE position, check that no extra air leaks from the footwell outlet (or duct) of the heater unit assembly.

>>B<< AIR MIXING DAMPER CONTROL CABLE CONNECTION




1.Set the Temperature control dial of the heater control assembly to MAX HOT position.
2.Turn the air mixing damper lever of heater unit to the MAX HOT position (turn the damper lever to the left until it stops) and then install the cable.
3.Insert the cable end into the temperature adjusting linkage pin of the heater unit assembly.

4.Insert the cable into the clip while engaging the E ring of the temperature adjusting cable into the locator of the heater unit assembly in direction of arrow.
5.After all of the components have been installed, operate the temperature adjusting knob from HOT to COOL and vice versa. The temperature adjusting linkages of the heater unit assembly should move smoothly from end position to end position.

>>C<< OUTSIDE/INSIDE AIR SELECTION DAMPER CONTROL CABLE CONNECTION




1.Set the inside/outside air changeover damper to the inside air recirculation position.
2.Se the inside/outside air changeover lever on the heater control panel to the inside air recirculation position.
3.Engage the cable end into the inside/outside air changeover link pin at the blower unit side of the heater unit assembly.

4.Engage the cable E-ring into the locator of the heater unit assembly to fit the cable into the clip.
5.Operate the inside/outside air changeover lever on the heater control panel from the inside air recirculation to the outside air positions and vice versa to check that the knob and its linkage run smoothly all the way.