Code No. P0132: Oxygen Sensor Circuit High Voltage <Vehicles with catalytic converter>










OPERATION




FUNCTION




TROUBLE JUDGMENT


Check Condition
Judgment Criterion

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III data list



  • Refer to Data List Reference Table .

    1. Item AC: Oxygen sensor

Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Go to Step 2 .

STEP 2. Connector check: C-21 oxygen sensor connector


Q. Is the check result normal?

Go to Step 3 .
Repair or replace the connector.

STEP 3. Connector check: D-246 engine-ECU <M/T> connector or D-217 engine-A/T-ECU <A/T> connector


Q. Is the check result normal?

Go to Step 4 .
Repair or replace the connector.

STEP 4. Check harness between C-21 (terminal No. 4) oxygen sensor connector and D-246 (terminal No. 108) engine-ECU <M/T> connector or D-217 (terminal No. 108) engine-A/T-ECU <A/T> connector.



  • Check output line for short circuit.

Q. Is the check result normal?

Go to Step 5 .
Repair the damaged harness wire.

STEP 5. Check harness between C-21 (terminal No. 2) oxygen sensor connector and D-246 (terminal No. 96) engine-ECU <M/T> connector or D-217 (terminal No. 96) engine-A/T-ECU <A/T> connector.


note Before checking harness, check intermediate connectors D-111 and D-225, and repair if necessary.

  • Check earthing line for short circuit.

Q. Is the check result normal?

Go to Step 6 .
Repair the damaged harness wire.

STEP 6. M.U.T.-III data list



  • Refer to Data List Reference Table .

    1. Item AC: Oxygen sensor

Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Replace the engine-ECU <M/T> or engine-A/T-ECU <A/T>.